What is top-load testing? Also known as column-crush, vertical load resistance and axial force resistance, top-load testing involves applying a downwards compressive force to a packaging container and measuring its resistance to deformation. More businesses than ever are focused on protecting the environment by reducing overall packaging and making it more recyclable.
XHD2 Load Cell Quickstart Guide 4 3 Put a test weight (which may be yourself or another person) at one end of the chute/crush and note the stable reading on the indicator. 4 Put the test weight at the other end of the chute/crush and note the stable reading on the indicator. 5 Remove the test weight and note whether the reading returns to zero. 6 If the two readings differ by …
We provide customers with advanced asphalt testing equipment, concrete testing equipment, soil testing equipment, and much more to allow professionals to examine materials for various aspects prior to building projects. Better testing equipment results in better building materials used in construction, making these projects safer and longer ...
TECHNICAL PARAMETERS. Application area Application soil type: Various types of soil and earth-rock mixed fillers with a particle size not larger than 1/4 of the bearing plate diameter Test influence depth: 0~500mm Working environment Temp.: -10ºC~40ºC humidity <90%HR. Handheld main unit Size: Screen size:3 inch Dimension:100×205×40mm Weight:0.8kg …
A test to determine the load and the displacement required to permanently deform or fully collapse the medical stent device. ... A sample is placed on the support plate in the orientation anticipated to have the least amount of crush resistance. The sample is compressed using a uniform rate of compression until final distance value defined is ...
10. Plate load test can be used to directly estimate the settlement of the footing. performed using standard test procedures such as outlined in ASTM D 1194-94 Bearing plate, round or square, varying in size, from 30 to 60 cm and thickness of about 2.5 cm are employed for the test. Normally a plate of size 30 cm is used in sandy soils and a larger size in clay soils.
The Plate Load Test and is normally used to measure the short term settlement of pavement sub-grade, temporary works platforms or building footings under their proposed design load. The value of settlement against load is then used to check that the soil meets design load settlement criteria. The test therefore is of use to both contractors and to specifying authorities and is …
The results of a plate-load test in a sand soil are shown below. The size of the plate is 0.25m x 0.25m. If a square column foundation (4m x 4m) that should carry a load of 8000kn, what is the estimated settlement of the foundation? Settlement (mm) 6 Load/unit area (kN/m²) 400 600 200 800 0 Load/unit area (KN/m²) 200 300 400 500 600 9 13 10 ...
Testing & Materials (ASTM) D1194 (1994) for the Plate Load Test (PLT). The high cost, technical and logistical complexity, and market availability of suppliers providing full scale load testing has led engineers to alternative test methods. Touma et al. (2016) described the development of the Rapid Plate Load Test (RPLT), a device to perform ...
A major benefit of this system is its ability to alternate speeds during top-load measurements. The test can be run at one speed until the compression plate touches the top of the sample, then applies a compressive load at a different speed, which is pre-programmed to run automatically without the need for an operator to intervene.
The plate load test is a field test, which is performed to determine the ultimate bearing capacity of the soil and the probable settlement under a given load. This test is very popular for the selection and design of the shallow foundation. For performing this test, the plate is placed at the desired depth, then the load is applied gradually ...